Services on Demand
Journal
Article
Indicators
- Cited by SciELO
Related links
- Similars in SciELO
Share
Latin American applied research
Print version ISSN 0327-0793
Abstract
GONZO, E.E. and GOTTIFREDI, J.C.. Heat and mass transfer limitations in monolith reactor simulation with non uniform washcoat thickness. Lat. Am. appl. res. [online]. 2010, vol.40, n.1, pp.15-21. ISSN 0327-0793.
In this contribution, effectiveness factor (?) calculations are performed by a perturbation and matching technique developed by the authors which takes into account both the intrinsic kinetic expression and external heat and mass transfer resistances. The simplified method of Papadias et al. (2000) was used to consider the non-uniform washcoat thickness usually present in monolith channels. As a result a global effectiveness factor (?0) is calculated at each point on the grid to simulate monolith reactor performance. The procedure was tested to predict experimental findings taking into account the actual kinetic expression to describe CO oxidation on Pt catalyst. Agreement among theoretical predictions and Ullah et al. (1992) and Holmgren and Andersson (1998) experimental results are fairly good.
Keywords : Monolith Reactor; Diffusion; Reactor Engineering; Effectiveness Factor.