SciELO - Scientific Electronic Library Online

 
vol.86 issue1Infective endocarditis in argentina. results of the eira 3 StudyEfficacy and Safety of Transfemoral Transcatheter Aortic Valve Replacement under General Anesthesia versus Local Anesthesia with Conscious Sedation author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista argentina de cardiología

On-line version ISSN 1850-3748

Abstract

MALDONADO, SEBASTIÁN et al. Usefulness of remote Monitoring of Pediatric Patients with Cardiac implantable electronic devices. Rev. argent. cardiol. [online]. 2018, vol.86, n.1, pp.30-34. ISSN 1850-3748.

Background: The aim of this study is to evaluate the usefulness of cardiac implantable electronic devices with remote monitoring system in a pediatric population and the limitations of its implementation in Argentina.

Methods: Twenty-seven patients receiving a cardiac implantable electronic device with remote monitoring system at Hospital Nacional Garrahan and Hospital Italiano de Buenos Aires were included in the study. The rate of events, complications and device-related therapies were evaluated. The anticipated actions taken in response to alert notifications were described. Mean follow-up was 46.6 ± 32.1 months.

results: Median age was 12.2 years (IQR: 8.75-13.3). An implantable cardioverter defibrillator device was placed in 7 patients (25.9%) and 20 (74%) underwent pacemaker implant. Five patients (18.5%) presented seven red alerts: 3 due to ventricular arrhyth-mia in monitoring zone of ventricular fibrillation and 4 due to lead dysfunction. Twelve patients (44%) presented a yellow alert: 6 due to lead dysfunction, 4 due to deactivation of the monitoring system because of lack of signal reception, one due to ventricular tachycardia and another with sinus tachycardia in monitoring zone of ventricular tachycardia. Active actions were taken in 9 pa-tients (33.3%) to manage the alert notification: the atrial lead was replaced in one patient and the ventricular in lead in another; in 2 patients non-compliance with pharmacological treatment and exercise limitation were detected and in the rest of the patients, the device was reprogrammed according to the abnormalities observed in the recording or capture.

Conclusions: Remote monitoring of cardiac implantable electronic devices is very useful in the pediatric population, allowing for the rapid detection and management of device failure or significant arrhythmias.

Keywords : Pacemaker; Artificial - Defibrillators; Implantable - Remote Sensing Technology/methods - Monitoring - Physiologic/ methods.

        · abstract in Spanish     · text in English     · English ( pdf )