SciELO - Scientific Electronic Library Online

 
vol.79 issue3Hemiprótesis de Austin Moore en fracturas mediales de cadera desplazadas: Tasa de mortalidad, infección y luxación en 91 pacientes con mal estado general author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista de la Asociación Argentina de Ortopedia y Traumatología

On-line version ISSN 1852-7434

Abstract

COSTA PAZ, Matías. Estudio comparativo con prótesis total de rodilla de alta flexión: Resultados funcionales y de rango de movimiento. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2014, vol.79, n.3, pp.142-148. ISSN 1852-7434.

Background: The purpose of this comparative study is to analyze functional results and the range of motion of the knee between two groups of patients with total knee arthroplasty using high-flex prosthesis (in one group) and with a conventional implant (in the other). Methods: Sixty-four patients were surgically treated with total knee arthroplasty with Zimmer NexGen®, USA. From this series, 22 patients (group A) were treated with high-flex design. Two cases with rheumatoid arthritis were excluded. Forty-two patients were treated with a conventional implant, 21 of them were excluded, and group B included 21 patients. Maximum flexion and extension were evaluated before and after surgery. Functional evaluation was performed with the Knee Society Score (KSS), the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), and an analogous visual scale. Results: The mean pre-surgical maximum flexion was 99° in group A and 106º in group B. Mean post-surgical maximum flexion in group A increased to 114º with an average increase of 15º and, in group B, to 118º with an average gain of 12º. There were no significant statistical differences (p <0.05). Pre-surgical KSS in group A was 36/48 and increased to 90/92. In group B, pre-surgical KSS was 46/49 and 94/90 after surgery. Conclusion: This study suggests that there are no significant differences in the range of motion, functional results, and radiographic evaluation in a high-flex total knee arthroplasty and a conventional design after one year of follow-up.

Keywords : Knee prosthesis; Arthroplasty; Flexion; High-flex design.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License