SciELO - Scientific Electronic Library Online

 
vol.84 issue3Hernia intraesponjosa de Schmörl sintomáticaHidrogeles de polimerizacion in situ para la regeneracion de cartilago articular author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista de la Asociación Argentina de Ortopedia y Traumatología

On-line version ISSN 1852-7434

Abstract

LOBOS CENTENO, Esteban A et al. Diferencias entre las membranas inducidas por diferentes implantes y cementos: Estudio experimental. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2019, vol.84, n.3, pp.285-295. ISSN 1852-7434.

Background: The objective of this study is to analyze and compare the characteristics of the membranes that form around cement spacers; as well as the one that develops around titanium and steel implants. Materials and Methods: 20 rabbits were divided into 2 groups of 10. In Group 1, an antibiotic-coated cement spacer was placed on the right femur, and a titanium elastic nail (TEN) on the left one. In Group 2, an antibiotic/steroid-coated cement spacer was placed on the right femur, and a steel peg on the left one. At 6 weeks, the membranes were removed and its macroscopic, imaging, biochemical and histological characteristics were evaluated. Results: Macroscopy: The membrane induced by the ATB-coated cement spacer was significantly wider, whereas the one induced by the steroid-coated cement spacer and the TEN was very thin and adherent. Microscopy: The membrane induced by the steroid-coated cement spacer showed less inflammation (p = 0.0502) and was similar to the one induced by the steel peg (p = 0.322). Steel pegs showed greater epithelial proliferation (p = 0.026), which was scarce on the membrane induced by the steroid-coated cement spacer (p = 0.071). There was a mild tendency towards less active vascular proliferation (p = 0.107) in the group of the steroid-coated cement spacer vs. the one without steroids. There were no differences between the steel peg and the TEN (p = 0.737). X-rays and CT showed no significant differences (p = 0.988). In MRIs, most of the responses indicated lack of osseointegration in the steel peg group due to metallic artifacts. Conclusions: Different materials (titanium, steel and cement) with different agents added to them (antibiotics and steroids), alter the membranes both macroscopically and histologically. The steroidcoated cement spacer showed less inflammation and fibrosis, less vascular proliferation, and thinner and adherent membranes.

Keywords : Cement spacer; Peri-implant membrane; Masquelet membrane; Antibiotic-coated cement.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License