SciELO - Scientific Electronic Library Online

 
vol.86 issue4Influencia de la fusión espinal en la orientación del implante acetabularUso de conos de metal trabecular para defectos óseos severos en cirugía de revisión de reemplazo total de rodilla author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista de la Asociación Argentina de Ortopedia y Traumatología

On-line version ISSN 1852-7434

Abstract

PEREA, Agustín O. et al. Análisis clínico-radiológico comparativo de tallos femorales no cementados planos de primera vs. segunda generación. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2021, vol.86, n.4, pp.475-482. ISSN 1852-7434.  http://dx.doi.org/https://doi.org/10.15417/issn.1852-7434.2021.86.4.1337.

Introduction: The design of the femoral implant is essential for its adaptation to the different types of femoral canals. The objective of this study is to describe the adaptability of the implant and the type of fixation (fill and fit) of second-generation flat femoral stems compared to first-generation femoral stems. Materials and Methods: We described the radiological characteristics of patients who had undergone bilateral total hip replacement between 2007 and 2020 in our institution with both a first-generation Accolade TMZF (Stryker Orthopedics) and a second-generation Accolade II (Stryker Orthopedics) flat cementless femoral implant. Demographic variables, adaptation, and canal filling were studied. The modified Harris Hip Score and the WOMAC index were analyzed. Results: Forty-two patients (84 cases) were included in the sample. In group 1 (Accolade TMZF) we obtained an average canal fill of 81% and in group 2 (Accolade II), we obtained an average of 84%. In group 1, the type of fixation (fit) was type 1 (60%), type 2 (16%) and type 3 (24%). In group 2, it was type 1 (88%), type 2 (7%) and type 3 (5%). The modified Harris Hip Score for group 1 was 88 and, for group 2, 87.5. The WOMAC score for group 1 was 2.5 and for group 2 it was 3. Conclusion: The adaptability of the implant is essential for primary stability and its osseointegration/biological fixation. This adaptability is more precise with second-generation flat femoral stems.

Keywords : Second-generation flat femoral stems; femoral adaptability; proximal mediolateral fixation.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )