SciELO - Scientific Electronic Library Online

 
vol.22 número3Observation of tags and hybrid layer of a single bottle conventional adhesive system and a self-etching adhesive system, on sound dentinThe effect of smoking on gingival crevicular fluid volume during the treatment of gingivitis índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Resumen

PEREIRA, Priscilla C et al. A comparison of the film thickness of two adhesive luting agents and the effect of thermocycling on their μTBS to feldspathic ceramic. Acta odontol. latinoam. [online]. 2009, vol.22, n.3, pp.191-200. ISSN 1852-4834.

The aim of the present study was to evaluate the effect of thermocycling (TC) on the microtensile bond strength (μTBS) of two luting agents to feldspathic ceramic and to measure their film thickness (FT). For the μTBS test, sixteen blocks (6.4 x 6.4 x 4.8 mm) were fabricated using a feldspathic ceramic, etched with 10% hydrofluoric acid, rinsed and treated with the silane agent. The ceramic blocks were divided into two groups (n= 8): Gr1: dual-cured resin cement and Gr2: flowable resin. The luting agents were applied on the treated surfaces. Microsticks (1 ± 0.1mm2) were prepared and stored under two conditions: dry, specimens immediately submitted to the μTBS test, and TC (6,000 cycles; 5°C-55°C). The μTBS was evaluated using a universal testing machine (1 mm/min). The μTBS data (MPa) were submitted to two-way ANOVA and Tukey’s test (5%). For the FT test (ISO 4049), 0.05 ml of each luting agent (n=8) was pressed between two Mylar-covered glass plates (150 N) for 180 seconds and light polymerized. FT was measured using a digital paquimeter (Model 727-2001). The data (mm) were submitted to one-way ANOVA. The luting cement did not influence the μTBS results (p=0.4467). Higher microtensile bond values were found after TC (20.5 ± 8.6 MPa) compared to the dry condition (13.9 ± 4.7 MPa), for both luting agents. The luting agents presented similar film thicknesses: Gr1- 0.052 ± 0.016 mm; Gr2- 0.041 ± 0.003 mm. The luting agents presented similar film thickness and μTBS values, in dry and TC conditions and TC increased the bond strength regardless of the luting agent.

Palabras clave : Adhesion; Surface treatment; Thermocycling; Film thickness; Luting agents; Ceramic.

        · resumen en Portugués     · texto en Inglés

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons