SciELO - Scientific Electronic Library Online

 
vol.24 número2Color stability of composites: effect of immersion mediaEffect of the topical application of triclosan in periodontally treated patients índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Acta odontol. latinoam. vol.24 no.2 Buenos Aires set. 2011

 

ARTÍCULOS ORIGINALES

Powder-liquid ratio and properties of two restorative glass ionomer cements

 

Vivian N. Zahra, Sergio G. Kohen, Ricardo L. Macchi

Department of Dental Materials and General Dentistry. School of Dentistry, University of Buenos Aires, Argentina.

CORRESPONDENCE Dr. Vivian N. Zahra Department of Dental Materials, School of Dentistry M.T. de Alvear 2142 (C1122AAH) Buenos Aires - Argentina E-mail: vnzahra@odon.uba.ar


ABSTRACT

Changes in the powder-liquid ratio of glass ionomer cements may affect some of its physical properties and acid erosion. The aim of this study was to evaluate the physical properties and acid erosion of two conventional restorative glass ionomer cements against ISO 9917-1:2007 standards after changing the powder-liquid ratio to an adequate consistency for luting indirect restorations. The methodology of ISO Specification 9917-1:2007 was applied to the powder-liquid ratio indicated by the manufacturer and to a modified ratio. Two restorative glass ionomer cements, ChemFil (Ch) (Dentsply) and Ionofil Plus (IP) (Voco), were used to evaluate film thickness, compressive strength, net setting time and acid erosion. Thickness was measured three times with a digital micrometer (Digimatic Mitutoyo Corporation). Sample size was five for each cement or condition. Compressive strength (Instron 1011, crosshead speed of 1 mm/min) was evaluated after 24 h immersion in water at 37°C. Sample size was five for each cement or condition. Setting time was evaluated for Ch and IP at 37°C. Sample size was three for each cement or condition. Specimen moulds (30 x 30 x 5 mm) with a central perforation of 5 mm in diameter and 2 mm depth were used for acid erosion tests. Erosion depth was measured with a micrometer gauge with a precision of 0.001 mm, before and after 24-hour immersion in a lactic acid-sodium lactate solution with pH 2.74 at 37°C. Sample size was five for each condition. Student’s t test was performed with a level of significance of p< 0.05 for each material and condition tested. Arithmetic mean (Standard Deviation). Powder-liquid ratio according to manufacturers: film thickness (in μm): Ch 220 (40), IP: 382 (5); compressive strength (in MPa) at 24 hs: Ch 166.3 (16,6), IP: 100 (10); net setting time (in min.) at 37°C: Ch 3.44 (0.3), IP: 5.26 (0.1) ; depth of acid erosion (in mm): Ch 0.15 (0.02), IP: 0.17 (0.02). Modified powder-liquid ratio: film thickness (in μm): Ch 23(1), IP:24(1); compressive strength at 24 hs (in MPa): Ch: 69.3 (14.6), IP: 46.5 (7.4); net setting time (in min.) at 37°C: Ch 5.72 (0.1) and IP 9.38 (0.1); depth of acid erosion (in mm): Ch 0.22 (0.02). Data were not recorded for IP because the sample disintegrated in the solution. Student’s t test was performed for both materials and conditions with a level of significance of p< 0.05. The difference between each condition tested was statistically significant (p<0.01). While changes in the powder-liquid ratio of a restorative glass ionomer cement can result in some of its properties having values that are not far from those required for luting cements according to ISO specifications, it did not meet the requirements for acid erosion.

Key words: Polyalkenoate cement; Physical properties; Solubility.

RESUMEN

Relación polvo-líquido y propiedades de dos ionómeros vítreos de restauración

Las modificaciones en la relacion polvo-liquido de los cementos de ionomero vitreo podrian afectar algunas de sus propiedades fisicas y su erosion acida. El objetivo de este trabajo fue evaluar las propiedades fisicas y la erosion acida de dos cementos de ionomero vitreo para restauracion, segun la Norma ISO 9917-1:2007, luego de modificar la relacion polvo-liquido alcanzando una consistencia adecuada para fijar restauraciones rigidas. Se aplico la metodologia de la Norma ISO con una relacion polvo-liquido segun indica el fabricante y una relacion modificada. Se evaluo espesor de pelicula, resistencia compresiva, tiempo de fraguado y erosion acida en dos cementos de ionomero vitreo para restauracion: ChemFil (Ch) (Dentsply), Ionofil Plus (IP) (Voco). El espesor de pelicula fue determinado con un micrometro digital (Digimatic Mitutoyo Corporation). El tamano de la muestra fue de 5 unidades para cada cemento o condicion experimental. La resistencia compresiva (Instron 1011, velocidad del cabezal 1 mm/min) fue evaluada luego de la inmersion en agua destilada a 37°C. n=5. El tiempo de fraguado se evaluo a 37°C. n=3. Se utilizaron soportes de probeta (30 x 30 x 5 mm) con una perforacion central de 5 mm de diametro y 2 mm de profundidad para los ensayos de erosion acida. La lectura de la profundidad de erosion de las probetas fue realizada con un calibre con 0.001 mm de precision, antes y despues de la inmersion durante 24 horas en una solucion de acido lactico-lactato de sodio con pH 2.74 en estufa a 37°C. n=5. La prueba de Student fue realizada con un nivel de significancia de p< 0.05 para cada material y condicion. Media Aritmetica (Desviacion Estandar) Relacion polvo-liquido segun el fabricante: espesor de pelicula (en μm): Ch 220 (40), IP: 382 (5); resistencia compresiva (en MPa) a las 24 hs: Ch 166.3 (16,6), IP: 100 (10); tiempo de fraguado (en min.) a 37°C: Ch 3.44 (0.3), IP: 5.26 (0.1) ; profundidad de erosion (en mm): Ch 0.15 (0.02), IP: 0.17 (0.02). Relacion polvo-liquido modificada: espesor de pelicula (en μm): Ch 23(1), IP 24(1); Resistencia  compresiva a las 24 hs (en MPa): Ch: 69.3 (14.6), IP: 46.5 (7.4); tiempo de fraguado (en min.) a 37°C: Ch 5.72 (0.1), IP 9.38 (0.1); profundidad de erosion (en mm): Ch 0.22 (0.02). No se registraron resultados para IP pues las muestras fueron desintegradas por la solucion. La Prueba de Student fue realizada para los dos materiales y condiciones experimentales con un nivel de significancia de p< 0.05. La diferencia entre cada condicion de ensayo fue estadisticamente significativa (p<0.01). Las modificaciones de la relacion polvo-liquido introducidas, pueden acercar las propiedades finales de un ionomero vitreo para restauracion a lo requerido para uno de fijacion segun las especificaciones de la Norma ISO, a excepcion de los requerimientos para erosion acida.

Palabras clave: Cemento polialquenoico; Propiedades fisicas; Solubilidad.


 

INTRODUCTION

A wide variety of dental cements are used in clinical practice to restore, lute or seal1. Conventional cements – like glass ionomers – rely on an acid-base reaction with formation of an ionic salt and generate a molecular adhesion to tooth structures. These materials can be supplied either in capsules or in a hand mix version (powder and liquid) that usually comes with a dispenser for preparing the correct powder-liquid ratio for the specific use designed by the manufacturers2. Many studies have shown that the amount of powder used changes between one operator and another, and it is presumed that changes in the powder-liquid ratio of glass ionomer cements can affect some of its physical properties 3 and acid erosion. Nevertheless, many practitioners deliberately change the powder-liquid ratio to obtain an adequate consistency for luting a restoration with glass ionomer cement. Clinical success is related to luting procedures as well as to the intrinsic characteristics of the luting material4. Any variation in the powder-liquid ratio will affect the mechanical properties of some cements1. In some commercial products, the hand mix glass ionomer cements are difficult to handle because neither the scoop nor the liquid dropper contain constant weight or volume. Although an accurate mixture of cement is essential, disparities occur3. Conventional glass ionomer cements are more sensitive in their reaction to higher liquid content than to higher powder content, and mixing variations happen even in cases where portioning aids were used3. The manufacturer’s specifications, including the powder-liquid ratio, are intended to produce minimal modifications in the final properties of the cement5.
Film thickness is influenced by manipulative variables such as mixing temperature and powder-liquid ratio1,6. One of the main features that affects it directly is the consistency of the luting material5,7-9. Depending on the particular clinical situation, the consistency of the material may adversely affect the film thickness and the correct seating of the restoration7,9. A luting material with increased viscosity requires more time to reach the optimal seating of the restoration before it sets as well as the application of higher seating forces to prevent marginal gaps7. Compressive strength is the most commonly used strength value to characterize dental cements10. In glass ionomer cements, it continues to increase over several weeks to about 200 MPa. This is thought to be due to reconstruction of a silicate network1. Any restorative dental materials must withstand the functional forces and exposure to various media in the mouth to achieve optimal clinical performance over a considerable period of time10. The aim of this study was to evaluate the film thickness, compressive strength, net setting time and acid erosion of two conventional restorative glass ionomer cements against the ISO 9917: 2003 requeriments, after changing the powder-liquid ratio to adequate consistency for luting indirect restorations.

MATERIAL AND METHODS

Tests were conducted under standarized temperature (21.C ± 2.C) and humidity (60% ± 10%). Table 1 shows the materials selected for the experiments with a powder-liquid ratio as indicated by the manufacturers and a modified ratio. Two restorative glass ionomer cements were used to evaluate film thickness, compressive strength, net setting time and acid erosion: ChemFil (Ch) (Dentsply) and Ionofil Plus (IP) (Voco GmbH). The methodology established by the ISO Specifications 9917-1:2007 for glass ionomer cements was used, except for film thickness, where the specification was adapted11 (Table 2).

Table 1. Products and Powder-Liquid Ratio used.

Table 2. ISO 9917-1:2007 Requirements for Glass Ionomer Cements.

Thickness was measured three times to the nearest 0.1 μm with a digital micrometer (Digimatic Mitutoyo Corporation) (Reading A). A measured amount equivalent to 0.1 ml of each cement mixture was placed between two glass plates (12 x 12 x 5). A 25 N load was applied on the upper glass plate with a hydraulic machine (CIFIC, Rosario, Argentina). Ten minutes later, the overall thickness of the plates and the cement was recorded (Reading B). The difference between readings A and B (difference between the thickness of the plates with and without the material between them) was considered as the final combined film thickness for the specimen being tested. Sample size was five for each cement or condition. For each cement, 4 x 5 mm cylinders were made in stainless steel moulds. Compressive strength was evaluated after 24h immersion in distilled water at 37.C, with an Instron Machine 1011, with a crosshead speed of 1 mm/min. Values for compressive strength were obtained in MPa by relating the application force (N) to the cylinder surface (mm2). Sample size was five for each cement or condition. Setting time was evaluated for Chemfil and Ionofil Plus at 37.C. One tenth of a milliliter of the cement was placed in a metal mould with a central perforation of 10 x 6 mm. Ninety seconds after the end of mixing, a metallic indentor with a flat end 1 mm in diameter was applied vertically onto the surface of the cement for 5 seconds. The indentations were repeated at thirty- second intervals (in the first case) and at ten-second intervals in the others, until the needle failed to make a complete circular indentation in the cement. The time elapsed between the end of mixing and the time when the needle failed to indent the material was considered as setting time for the material tested. Sample size was three for each cement or condition.
Acid erosion was determined using 30 x 30 x 5 mm specimen moulds with a central perforation of 5 mm in diameter and 2 mm depth. Erosion depth was measured with a micrometer gauge with a precision of 0.001 mm, before and after 24 hour immersion in a lactic acidsodium lactate solution with pH 2.74 at 37.C. Both materials were tested with a powder-liquid ratio as indicated by the manufacturer and a modified ratio. Sample size was five for each condition and experimental conditions were compared using Student’s t test.

RESULTS

Table 3 shows means and standard deviations as well their 95% confidence intervals for the film thickness, compressive strength, setting time and acid erosion of the glass ionomer cements tested, with a powder-liquid ratio as indicated by the manufacturers and a modified ratio. Student’s t test was performed for each material and condition with a level of significance of p< 0.05. The difference between each condition tested was statistically significant (p<0.01) for film thickness and compressive strength as shown by the lack of overlap of the confidence intervals. When the powder-liquid ratio of Ionofil Plus was modified, it did not meet the minimum required compressive strength specification (50 MPa). Setting time was studied at 37°C with a powder-liquid ratio according to manufacturers and a modified ratio. Ionofil Plus did not meet the ISO Specification requirements for a luting cement when the powder- liquid ratio was modified, because it exceeded the 8 minutes maximum expected (9.38 min). Student’s t test showed that the difference between each material and condition tested was statistically significant (p<0.01), and that there were statistical differences for both materials because of the lack of overlap in the confidence intervals.

Table 3. Properties of Glass Ionomer Used.

The depth of acid erosion (mean and standard deviation in mm) was evaluated for both materials. Student’s t test showed that the difference between each condition tested for Chemfil was statistically significant (p<0.01). Chemfil did not meet the requirements of ISO 9917-1:2007 when the powder-liquid ratio was modified. Data were not recorded for Ionofil Plus specimens when the powder-liquid ratio was modified because the samples disintegrated in the solution.

DISCUSSION

Conventional glass ionomer cements are frequently used in dental practice to restore or lute restorations of dental and other structures1,4 because of its advantages, such as fluoride ion release, physicochemical bonding to tooth structure and a low coefficient of thermal expansion7. The correct choice of a luting agent is key to success in indirect dentistry and dependent on the clinical situation, based on its physical, biological and handling properties7.
Changes in the powder-liquid ratio of conventional glass ionomer cements may alter some physical properties. One of them is the film thickness, which depends on multiple factors1,2,6,8,9, including manipulation, temperature of the mix, consistency, handling, working and setting time and time elapsed after mixing1,3,- 6,8. Consistency is considered one of the principal features affecting the film thickness of any luting material.8 In this study, when the powder-liquid ratio was modified to adequate consistency for a luting cement, both materials tested, Chemfil and Ionofil Plus met the 25 μm maximum required by ISO 9917, as shown by the lack of overlap of the confidence intervals. Compressive strength has been used as a predictor of clinical performance. For a restoration to function correctly, the cement must have sufficient strength to resist fracture1. Both materials tested met ISO specifications regarding compressive strength when the powder-liquid ratio was used according to manufacturers. On the other hand, Ionofil Plus did not fulfill the requeriments when the modified powder- liquid ratio was used because it did not reach the minimum value of 50 MPa. One study has shown that the compressive strength of encapsulated glass ionomer cements which have high viscosity produce more favourable mechanical properties.3 The reason was the lower probability of air inclusions during the mechanical mixing4. In contrast, more fluid materials produced lower porosity by hand mixing than by mechanical mixing. It appears that the lower viscosity material more readily causes air inclusions and a type of froth is formed during the rapid mixing process. The slower hand-mixing process helps to avoid these inclusions and may cause the collapse of the air-bubbles3.
Net setting time was evaluated at 37.C. Both Chemfil and Ionofil Plus took longer to set (double) when the powder-liquid ratio was modified. This was more noticeable in Ionofil Plus. The setting time of luting agents is influenced by temperature. As temperature increases, the working and setting times of glass ionomer cements decrease1. Although at 37.C (according ISO 9917) the net setting time of any luting material is expected to be shorter than 8 minutes, Ionofil Plus exceeded the specification values. Different strategies have been developed to obtain success in cementation because it depends on multiple factors1,5,8,9. The luting procedure has the potential to adversely influence marginal adaptation9, so the ability of the cement to withstand exposure to different media in the mouth10, to avoid water sorption and dissolution, is essential to clinical success4. Acid erosion tests were carried out for both materials and conditions, but the results did not meet the 0.17 mm maximum required for luting materials according ISO Specifications. Ionofil Plus specimens with the modified powder-liquid ratio disintegrated a few minutes after immersion in the lactic acid-sodium lactate solution.
Moreover, the acidity of the storage medium is not the only factor responsible for the degradation of cements. The ability to resist dissolution has been found to vary with the composition of the medium, and not simply with its pH10. The acid erosion tests provided an idea of the performance of the two restorative glass ionomer cements selected at adequate consistencies for luting restorations. There is not a single specific material that could be used for the entire range of procedures, but the correct luting agent must be selected according to its mechanical and physical properties in order to ensure high clinical performance1,2,4,7,8.

CONCLUSION

It can be concluded that, while changes introduced in the powder-liquid ratio of a restorative glass ionomer cement can result in values for some properties that are not far from those required for luting cements, the requirements of ISO specifications for acid erosion could not be met.

ACKNOWLEDGEMENTS

Financed within Project O009, Project O011 and with a scholarship granted to the first author by the University of Buenos Aires, Argentina. The authors would like to thank Dentsply Argentina and especially Mr. Raul Ripoll (Country Manager) for the materials and their profiles used in this paper, Dr. Delia Takara for her support in carrying out acid erosion tests, Dr. Analia Mosquera for her assistance with some tests and Mr. Javier Faig for his support with the tests done in this study.

REFERENCES

1. Rosenstiel SF, Land MF, Crispin BJ. Dental luting agents: A review of the current literature. J Prosthet Dent 1998;80: 280-301.         [ Links ]

2. Wassell RW, Barker D, Steele JG. Crowns and other extracoronal restorations: try-in and cementation of crowns. Br Dent J 2002; 193:17-20, 23-28.         [ Links ]

3. Behr M, Rosentritt M, Loher H, et al. Changes of cement properties caused by mixing errors: The therapeutic range of different cement types. Dent Mat 2008;24:1187-1193.         [ Links ]

4. Diaz-Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. J Prosthet Dent 1999;81:135-141.         [ Links ]

5. Zahra VN, Abate PF, Macchi RL. Film thickness of resin cements used with adhesive systems. Acta Odontol Latinoam 2008;21:29-33Links ] Helvetica, sans-serif">.

6. Osman SA, McCabe JF, Walls AW. Film thickness and rheological properties of luting agents for crown cementation. Eur J Prosthodont Restor Dent 2006;14:23-27.         [ Links ]

7. Attar N, Tam LE, McComb D. Mechanical and Physical Properties of Contemporary Dental Luting Agents. J Prosthet Dent 2003;89:127-134.         [ Links ]

8. Wilson PR. Crown behavior during cementation. Review. J Dent 1992;20:156-162.         [ Links ]

9. Tan K, Ibbetson R. The effect of cement volume on crown seating. Int J Prosthodont 1996;9:445-451.         [ Links ]

10. McKenzie MA, Linden RW, Nicholson JW. The physical properties of conventional and resin-modified glass ionomer dental cements stored in saliva, proprietary acid beverages, saline and water. Biomaterials. 2003 Oct;24(22):4063-4069.         [ Links ]

11. International Organization of Standardization. Dental- Water-Based Cements ISO No. 9917-1:2007;1-22.         [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons