SciELO - Scientific Electronic Library Online

 
vol.36 número2Evaluación de diferentes métodos de extracción de gADN en Candida albicans y Candida dubliniensis en muestras subgingivales en Argentina índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión impresa ISSN 0326-4815versión On-line ISSN 1852-4834

Resumen

SILVA JUNIOR, Eduardo V; BASTING, Roberta T; TURSSI, Cecilia P  y  FRANCA, Fabiana MG. Precision of polyether ether ketone (PEEK) or cobalt-chrome implant bar fit to implants after mechanical cycling. Acta odontol. latinoam. [online]. 2023, vol.36, n.2, pp.71-77.  Epub 31-Ago-2023. ISSN 0326-4815.  http://dx.doi.org/10.54589/aol.36/2/71.

Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants. Aim: The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics. Materials and Method: This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey’s test at 5% significance level. Results: No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups. Conclusions: The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.

Palabras clave : PEEK; Dental prosthesis; Mouth rehabilitation.

        · resumen en Portugués     · texto en Inglés     · Inglés ( pdf )