SciELO - Scientific Electronic Library Online

 
vol.87 número6Análisis radiográfico de los parámetros espinopélvicos obtenidos con el dispositivo de TLIF anterior. Estudio multicéntricoValidación al español del instrumento Self-Administered Patient Satisfaction Scale (SAPS) para reemplazo total de cadera o de rodilla índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista de la Asociación Argentina de Ortopedia y Traumatología

versión On-line ISSN 1852-7434

Resumen

CASTELLINI, Jorge. Parámetros biomecánicos de la función del pie medidos en el consultorio del especialista en Ortopedia y Traumatología. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2022, vol.87, n.6, pp.756-764. ISSN 1852-7434.  http://dx.doi.org/https://doi.org/10.15417/issn.1852-7434.2022.87.6.1557.

Introduction: Dynamic studies of foot function are usually carried out in highly complex gait analysis laboratories. The objective of this study was to analyze functional parameters using a force platform in a series of asymptomatic patients evaluated in an outpatient clinic. Materials and Methods: Crosssectional study, which included a consecutive series of volunteer asymptomatic patients who underwent a force platform measurement (TekScanMatScan®, Boston, MA, USA) between 2014 and 2020, in the City of Buenos Aires, Argentina. Results: 316 records were included, corresponding to 158 individuals with bilateral measurements. Most were women (66.5%), with a mean age of 47 years (SD 16.1). Fourteen variables were evaluated, corresponding to parameters of force, trajectory, and contact time. The total contact time was 0.79 seconds (SD 0.09), and the COF time according to the region of the foot was 20% in the heel, 26% in the midfoot, and 46% in the forefoot. The CPEI (Center of Pressure Excursion Index) value was 16.55% (SD 7.14). Conclusion: Foot functional parameters in asymptomatic patients are presented. The contact time of the foot on the ground, the force in the heel, midfoot, and forefoot, and the force trajectory were measured. No ionizing radiation was used. These findings could be used as reference values to detect pathological gaits.

Palabras clave : Force; center of force; biomechanics; gait analysis; force trajectory; ground reaction force.

        · resumen en Español     · texto en Español     · Español ( pdf )