SciELO - Scientific Electronic Library Online

 
vol.53 número4Aplicación de Seis Sigma en el Laboratorio ClínicoRol de los estreptococos del grupo Streptococcus anginosus en infecciones de piel y partes blandas: reporte de 3 casos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

Compartilhar


Acta bioquímica clínica latinoamericana

versão impressa ISSN 0325-2957versão On-line ISSN 1851-6114

Resumo

DUBOSCQ, Cristina et al. Utilización de un dispositivo portátil para monitorear la relación internacional normalizada en pacientes con anticoagulante lúpico positivo. Acta bioquím. clín. latinoam. [online]. 2019, vol.53, n.4, pp.539-543. ISSN 0325-2957.

The certainty of the value of the international normalized relation (INR) assay to control dicoumarin anticoagulation in patients with positive lupus anticoagulant (LA) is unknown especially for the point of care testing (POCT). The aim of this work was to investigate if there was a correlation between the INR values obtained by the traditional method and those obtained with a POCT in patients with positive LA. The population under study were 35 patients anticoagulated by thromboembolic disease with a persistent positive LA, whose INR was determined at the same time by the traditional method and with CoaguChek during 4 consecutive controls. The INR range was 1.9 to 5.60 and the RIN-POCT was between 2.0-4.92. The comparison of INR vs. INR - POCT showed r=0.98, slope: 1.56 (0.98-1.12) and ordered to the origin -0.088 (-0.282-0.007). The bias was 2.1%. For an INR level lower than 3.5 (n=136 controls) the average INR difference was 0.17 with a range of 0.01-0.56. One patient, with triple positivity showed a difference between both methods greater than 0.4. in two controls. For INR greater than 4.5, the degree of concordance is lower but has no clinical implications. The data obtained show that there is a good correlation between the traditional INR and the CoaguChek. The results of INR obtained by CoaguChek in patients studied with positive LA are useful for clinical practice. Due to the large diversity of POCT, the results cannot be extrapolated to other devices. Given the heterogeneity of antiphospholipid antibodies, it is advisable to test in each patient whether there is a good agreement between the traditional INR and INR-POCT.

Palavras-chave : Anticoagulation; International normalized relation; CoaguChek; Lupus anticoagulant.

        · resumo em Português | Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons