SciELO - Scientific Electronic Library Online

 
vol.57 número4Evaluación de la estabilidad de parámetros hematológicos en muestras pediátricas bajo diferentes condiciones de almacenamiento determinados en un analizador Sysmex XN índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

Compartilhar


Acta bioquímica clínica latinoamericana

versão impressa ISSN 0325-2957versão On-line ISSN 1851-6114

Resumo

MARTIN, Hugo Guillermo; FERNANDEZ, Virginia Pilar; KIENER, Andrea Gisel del Milagro  e  DE ELIAS BOQUE, Rafael Francisco. Desempeño del analizador de orinas Laura XL-Erba Mannheim en comparación con el iRICELL-Beckman Coulter en una población general. Acta bioquím. clín. latinoam. [online]. 2023, vol.57, n.4, pp.2-2. ISSN 0325-2957.

The objectives of this work were to evaluate the performance of the Laura XL® Erba Mannheim urine analyzer, in comparison with the iRICELL® Beckman Coulter analyzer, and to assess the determination of semiquantitative urinary protein as screening in its study, establishing a cut-off point for its quantification. A total of 225 urine samples were simultaneously processed. pH, density, turbidity, colour, hemoglobin, glucose, ketones, nitrites, proteins, and number of positive reactive strips were evaluated; and epithelial cells, leukocytes, red blood cells and criteria for normality of the sediment were evaluated by microscopy. Positive urinary proteins per strip were quantified on a Modular COBAS® 8000 (Hitachi-Roche). Cohen’s Kappa concordance coefficient (k) and Spearman’s correlation index were used. Little agreement was obtained in turbidity (k=0.334), good agreement in colour (k=0.681), hemoglobin (k=0.620), glucose (k=0.677), ketones (k=0.768), nitrites (k=0.827), positive test strips (k=0.620), epithelial cells (k=0.783), leukocytes (k=0.745) and red blood cells (k=0.609); very good agreement for proteins (k=0.842) and sediment normality criteria (k=1,000). Statistically significant correlation in pH (r=0.8064; p<0.0001), density (r=1.000; p<0.0001), urinary protein (rs=0.9157; p<0.0001) compared with COBAS® 8000. A satisfactory performance of Laura XL® was concluded, showing a performance consistent with the needs and regulations of this institution, and its usefulness is endorsed as a screening test for the assessment of urinary proteins, establishing the quantification of urines that present 1+ or more per strip in Laura XL®. Software improvements are considered.

Palavras-chave : Complete urine study; Urianalysis; Urine analyzer; Comparison of methods; Proteinuria; Laura XL analyzer; iRICELL analyzer.

        · resumo em Português | Espanhol     · texto em Espanhol     · Espanhol ( pdf )