SciELO - Scientific Electronic Library Online

 
vol.37 número1Análise da morfologia e simetria do sistema de canais radiculares de incisivos, pré-molares e molares inferiores usando a TCFCSuco de apaí provoca o manchamento do glaze do cimento de ionomero de vidro modificado por resina índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Acta Odontológica Latinoamericana

versão impressa ISSN 0326-4815versão On-line ISSN 1852-4834

Acta odontol. latinoam. vol.37 no.1 Buenos Aires jan. 2024  Epub 30-Abr-2024

http://dx.doi.org/10.54589/aol.37/1/34 

ORIGINAL ARTICLE

Efficacy of WaveOne Gold and ProDesign RT systems in removing filling material: a micro-CT analysis

Eficácia dos sistemas WaveOne Gold e ProDesign RT na remopáo material obturador: uma análise micro-CT

1Faculdade Sao Leopoldo Mandíc, Instituto de Pesquisas Sao Leopoldo Mandic, Campiñas, Brazil.

2University of Sao Paulo, Bauru Dental School, Department of Dentistry, Endodontics and Dental Materials, Bauru, Brazil

3Universidade Iguaçu (UNIG), Departamento de Endodontia e Pesquisa Odontológica, Nova Iguaçu, Rio de Janeiro, Brasil.

4KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research group & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium.

5Laboratory of Orofacial Pathologies, Imaging and Biotherapies, School of Dentistry, Laboratoire d'Excellence INFLAMEX, Université Paris Cité, URP 2496, Montrouge. France.

6Universidade Federal do Rio de Janeiro, Programa de Engenharia Nuclear, Rio de Janeiro, Brazil

7Universidade Estadual de Campinas, Unicamp, Piracicaba, Brazil

ABSTRACT

The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy.

Aim

The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT.

Material and Method

Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student ’s t-test was performed to account for multiple observationsper sample, significance was set at 5%.

Results

Student ’s t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918).

Conclusión

Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.

Keywords: micro CT- root canal retreatment; reciprocal systems; rotary systems

RESUMO

A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia.

Objetivo

O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT.

Material e Método

Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%.

Resultados

O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918).

Conclusao

O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.

Palavras-chave: micro CT; retratamento do canal radicular; sistemas reciprocantes; sistemas rotatórios

INTRODUCTION

Nonsurgical endodontic retreatment is the first choice when endodontic treatment has failed. The remaining filling material may harbor necrotic tissue and microorganisms responsible for endodontic failure 1 . Efficient removal of filling material, new cleaning and shaping, irrigation, and access to the apical foramen are critical to the health of the periapical tissues 2 .

Studies have evaluated the percentage of root canal filling material removed with rotary and reciprocating systems, with rates ranging from 59.4% to 96.9 3-6 . Due to the anatomical complexity of the root canal system and the limitation of instrument design, complete removal ofthe root canal filling material can be difficult or even impossible 7 , 10 , especially in the apical region. The WaveOne Gold (WOG - Dentsply-Sirona, Ballaigues, Switzerland) reciprocating system, which is made of a heat-treated M-wire alloy, has shown good results in removing filling material 11 although it has not been recommended for use in retreatment. The ProDesign RT (PRT - Bassi / Easy Equipamentos Odontológicos, Belo Horizonte, Brazil) rotary system was developed for removing filling material from root canals. It is made of a CM alloy and has a triple helix cross-section. According to the manufacturer, PRT files remove approximately 90% of endodontic filling material without the use of solvents.

Micro-CT enables three dimensional (3D) evaluation of the amount of remaining filling material due to its precision for enabling visualization of morphological features with specimen preservation 5 , 11 , 12 . The aim of this study was to use micro-CT to evaluate the amount of remaining filling material after retreatment of human mandibular canines using the WOG or PRT systems and the null hypothesis is that there is no difference between the systems in root canal filling removal.

MATERIAL AND METHOD

G*Power 3.1 software (Heinrich Heine College, Duesseldorf, Germany) was used to calculate power with a power of P = 95% and a = 5%, and a t test for independent samples was applied. The ideal sample size for each group should be at least 10 teeth, but 10 additional samples were added per group to compensate for possible loss.

Forty mandibular canines with moderately curved roots (10° to 20°) were selected from a pool of 432 teeth. All specimens were scanned in micro-

CT (SkyScan 1173, Bruker, Kontich, Belgium) at 70 kV and 114 mA, with a 1-mm-thick aluminum filter, exposure time 320 milliseconds, pixel size 12.1 pm, rotation step 0.8°, and rotation 360° along the vertical axis. The files were then reconstructed into a three-dimensional data set using the software NRecon v1.6.1.0 (Bruker micro-CT), with beam hardening correction 50%, ring artifact correction 10, and smoothing 5. The volume of interest extended from the cementoenamel junction to the root apex, resulting in the acquisition of 600 to 700 axial slices per sample. CTAn v.1.14.4 and CTVol v.2.2.1 software (Bruker Micro-CT) were used to evaluate root canal morphology in terms of volume, surface area and 3D configuration. Teeth were then paired based on the anatomical similarities of preoperative canal volume, canal length of approximately 18 mm, canal surface area and 3D configuration.

This study included teeth with a single canal and complete root formation, and excluded teeth with pulp calcifications, resorptions, root fractures or canals whose patency was not achieved. Teeth were washed under running water, the root surface was cleaned ultrasonically, and kept hydrated in saline solution until the start of the experiment. Tooth length was standardized to 18 mm by partially crowns removal with a diamond disk (FKG Dentaire, La Chaux-de-Fonds, Switzerland). Each tooth was radiographed in the mesiodistal and buccolingual directions to verify for presence of a single canal and the degree of curvature of the roots. Periapical radiographs were performed with an X-ray unit (Procion, Ribeirao Preto, Brazil) coupled to a digital sensor (Elite - Schick, Sao Paulo, Brazil), with a distance of 10 cm between tooth and film, using the following exposure parameters: 0, 08s; 70 kV, 8 mA. To measure root canal length, a K# 10 hand file (Dentsply Maillefer, Ballaigues, Switzerland) was inserted in the tooth under an optical microscope at 20* magnification until the tip of the file was visible through the apical foramen. Working length (WL) was determined by subtracting 1 mm from this measurement.

The canals were instrumented at WL using the ProTaper Next system (Dentsply-Sirona) up to the X2 instrument (25.06). Patency was maintained with a #10 K instrument extended 1 mm beyond WL. Root canal instrumentation was performed by a single operator according to the manufacturer’s recommendations for speed and torque, using an electric motor (Dentsply-Sirona) under a surgical microscope with 8x magnification. At each instrument change, irrigation was performed with 5 mL of 2.5% NaOCl (Fórmula e Aqao, Sao Paulo, Brazil). The smear layer was removed at the end of instrumentaron with 17% EDTA (Fórmula e Aqao, Sao Paulo, Brazil) agitated for 3 minutes with the EasyClean instrument (Bassi / Easy).

The teeth were dried with absorbent paper and filled using Tagger Hybrid Technique 13 , with an X2 cone (Dentsply-Sirona) and AHPlus (Dentsply-Sirona). To assess the quality of the filling, new radiographs were taken with the same parameters in the mesio-distal and bucco-lingual directions. The crowns were sealed with Coltosol (Whalent, Cuyaho, OH) and stored at 100% humidity and 37 °C for 30 days. After this period, the teeth were paired with micro-CT for specimens based on the volume of the original filling material. The teeth were divided into 2 groups according to the system. In the WOG 25.07 group (n = 20), the filling material was removed with the instrument in a reciprocating motion using the WaveOne ALL program driven by a 6:1 contra-angle handpiece (Sirona, Bensheim, Germany) powered by an electric motor (VDW Silver - VDW GmbH, Munchen, Germany). In the PRT 25.08 group (n = 20), the Easy SI endodontic motor (Bassi/Easy) was used to remove the filling material in a rotary motion at a speed of 900 rpm and torque 4N.

In both groups, the instruments were used with reciprocating motion with an amplitude of 3 mm and with a brushing motion until the WL was reached. Patency was maintained with a K #15 hand file. After each of the three in-and-out movements of the automated instruments, they were removed and cleaned with sterile gauze soaked in 70% alcohol. Each instrument was used only once and then discarded. Irrigation was performed with 20 mL of 2.5% sodium hypochlorite (Fórmula e Aqao), using a 21 mm Navitip 30G needle (NaviTip, Ultradent, South Jordan, USA). The final irrigation protocol consisted of 5mL of 2.5% NaOCl using a disposable syringe (Injex Indústrias Cirúrgicas Ltda) and a Navitip 30 G needle.

Micro-CT analysis

After obturation and removal of the filling material, a new microtomographic scan was performed to evalúate the amount of filling material remaining in the canals along the entire length with a SkyScan 1173 X-ray device (Bruker micro-CT) with the same parameters as described above.

Images were reconstructed using the CTAn v.1.15 software (Bruker micro-CT), and the volumes of obturation material (mm3) were determined according to the obturation and retreatment procedures. All measurements were performed for the entire canal volume and for each third: cervical, middle, and apical. Subsequently, 3D models were created and visualized using the software CTVol v.2.3 (Bruker microCT).

Statistical analysis

The percentage of the volume of filling material remaining after instrumentation was determined for each thir and the entire root canal. The data were subjected to log 10 transformation before statistical analysis. The data obtained were analyzed for their coefficient of variation and passed the D’Agostino & Pearson normality test, thus assuming a homogeneous distribution of the data. Student’s t-test was performed to account for multiple observations per sample. All analyses were performed using IBM SPSS version 25.0 software (IBM Corp. Armonk, USA), with p < 0.05.

RESULTS

Microtomographic images showed residual filling material in all specimens ( Fig. 1 ). Student’s t-test showed that there was no statistical difference in the volume of remaining filling material between the two systems, either in the apical (p = 0.392), middle (p = 0.065) or cervical (p = 0.918) thirds ( Table 1 ) but in the intragroup evaluation, differences were found (p=0.013).

Fig. 1 Images of representative micro-CT reconstructions of the root canals in mesiodistal view showing the remaining filling material before (A) and after retreatment (B). 

Table 1 Mean value (standard deviation) of the volume (mm3) of initial filling material (IFM) and remaining filling material (RFM), and mean value (standard deviation) of the percentage (%) of the volume of the filling material remaining after treatment with the PRT and WOG instruments  

  WaveOne Gold 25/.07 ProDesign RT 25/.08  
Thirds IFM RFM % IFM RFM %
Apical 0.98 (0.23) 0.03 (0.06) 2.82 (6.44) 1.12 (0.37) 0.04 (0.05) 3.65 (4.13)
Medium 2.30 (0.42) 0.02 (0.04) 0.74 (1.52) 2.56 (0.65) 0.04 (0.05) 1.56 (2.39)
Cervical 4.39 (1.00) 0.02(0.04) 0.86 (1.24) 4.38 (0.98) 0.04 (0.05) 2.07 (2.12)

DISCUSSION

Efficiency in removing filling material from root canals may depend on variables such as diameter and taper of the endodontic instrument, type of alloy, heat treatment, cross-section, and kinematics of movement 14 . Therefore, the objective of this study was to evalúate the ability to remove filling of two systems with different characteristics and kinematics: Wave One Gold and ProDesign Logic RT.

ProDesign Logic RT is a rotary system with multiple instruments (#30.10; #25.08 and #20.06). It has a CM-wire treatment and a triple helix section, and fixed taper that gives it a greater volume of metallic mass, favoring contact with the canal walls 15 . Wave One Gold is a reciprocating single file system (#20.07; #25.07; #35.06 and #45.05) made of NiTi with special gold heat treatment, with parallelogram-shaped cross-section and variable taper that decreases in the cervical direction 5 . Despite the differences between the instruments in terms of manufacturing process, kinematics and taper, no significant difference in the removal of filling material in the cervical, middle, and apical thirds was found in the present study (p > 0.05). Therefore, the null hypothesis was accepted. Although ProDesign Logic RT (25.08) has a larger taper than Wave One Gold Primary (25.07), there was no difference in the amount of filling material removed (p>0.05) between the tested systems. This result confirms previous studies showing that Wave One Gold Primary (25.07) has the same effectiveness in removing filling material as reciprocating systems with a larger taper such as Reciproc (25.08) and Reciproc Blue (25.08), and rotary systems such as Protaper Gold F2 (25.08) 14 . One reason that may explain why the Wave One Gold instrument and the ProDesign Logic RT have similar ability to remove filling material is that the WOG has a parallelogram cross-section with two cutting edges and asymmetricmotion, which may have reduced the percentage of remaining filling material 16 . The absence of significant differences between the systems for extrusion and intracanal filling material removal may also be associated with the standardized conditions of root canal anatomy, irrigation, and working length 3 , 6 , 8 , 9 , 23 . In these conditions, studies have shown that differences in taper, tip and cross-sectional shape, as well as the operation mode and the number of instruments used, fail to promote significant differences in filling removal 3 , 6 , 8 , 9 , 23 .

The difference in kinematics between the two systems studied did not affect the effectiveness of filling material removal. Previous studies have also found no difference in ability to remove filling material between rotary and reciprocating systems 17-19 . Moreover, a systematic review20concluded that reciprocating and rotary systems have similar retreatment capabilities. However, some studies have shown better performance with reciprocating systems 21 , 22 , while others have shown better performance with rotary systems 23 , 24 . This divergence in results could be due to the method used to evaluate the removal, the endodontic sealer, and/or the filling technique used.

Although the ProDesign Logic RT system provides a sequence of three instruments, only the 25.08 instrument was used in the current study, in order to approximate the diameter of the WOG 25.07 instrument and improve the comparison parameters. The PRT 30.10 instrument could be more effective because instruments with a larger tip diameter may remove more filling material than instruments with smaller diameters 14 .

Some limitations regarding the methodology of this study should be highlighted. Straight roots were used to facilitate specimen standardization and adequate specimen pairing. Oval canals were selected because this type of anatomy presents challenges for chemical-mechanical preparation and nonsurgical retreatment. AH-Plus epoxy-based endodontic sealer was used due to its excellent sealing ability, dimensional stability and flowability. Micro-CT is the assessment method commonly used in non-surgical endodontic retreatment studies 5 , 22 . Studies show that additional irrigation with agitation techniques improves the removal of filling material 23 , 25 , 26 . A previous study using oval canals of mandibular premolars compared the efficacy of the XP-Endo Finisher R and R1-Clearsonic inserts in removing filling material remnants from oval canals using micro-CT and concluded 82.1% and 64.6% in the entire canal for XP-Endo Finisher R and R1-Clearsonic (P < 0.05) 9 . Another study showed similar results with Photon-induced photoacoustic streaming (PIPS) using XP-Endo Finisher and Passive ultrasonic irrigation (PUI) to remove residual root canal filling material from oval canals. Filling material was removed up to size X4 using ProTaper Next system, and the supplementary procedures were performed. The authors demonstrated that PIPS could reduce residual root canal filling materials to a similar extent as PUI and XPF 27 . Therefore, the results of the current study should be evaluated with caution as only conventional irrigation with a syringe was used, which is the most common irrigation system worldwide.

CONCLUSIONS

The ProDesign RT and WaveOne Gold systems significantly reduced filling material in single-rooted canines with oval canals with similar results, although a residual amount of filling material remained following the use of both instrument systems. Further studies are needed to evaluate instruments that can compensate for the limitations of mechanical root canal preparation.

REFERENCES

1 Siqueira JF, Rojas IN. Clinical implications and microbiology of bacterial persistence after treatment procedures. J Endod. 2008;34(11):1291-1301.e3. https://doi.org/10.1016/j.joen.2008.07.028 [ Links ]

2 Bernardes RA, Duarte MAHH, Vivan RR, Alcalde MP, et al. Comparison of three retreatment techniques with ultrasonic activation in flattened canals using micro-computed tomography and scanning electron microscopy. Int Endod J. 2016;49(9):890-7. https://doi.org/10.1111/iej.12522 [ Links ]

3 Monteiro TM, Cortes-Cid VO, Marceliano-Alves MFV, et al. Intracanal removal and apical extrusion of filling material after retreatment using rotary or reciprocating instruments: A new approachusing human cadavers. Int Endod J. 2023 Oct27. https://doi.org/10.1111/iej.13990 [ Links ]

4 Pacheco-Yanes J, Gazzaneo I, Campello AF, Marceliano-Alves MF, et al. Planned Apical Preparation Using Cone-Beam Computed Tomographic Measures: A Micro-Computed Tomographic Proof of Concept in Human Cadavers. J Endod. 2022;48(2):280-6. https://doi.org/10.1016/j.joen.2021.11.016 [ Links ]

5 Canali LCF, Duque JA, Vivan RR, Bramante CM, et al. Comparison of efficiency of the retreatment procedure between Wave One Gold and Wave One systems by Micro-CT and confocal microscopy: an in vitro study. Clin Oral Investig. 2019;23(1):337-43. https://doi.org/10.1007/s00784-018-2441-y [ Links ]

6 Alves FRFF, Marceliano-Alves MF, Sousa JCN, Silveira SB, et al. Removal of root canal fillings in curved canals using either reciprocating single- or rotary multi-instrument systems and a supplementary step with the XP-Endo Finisher. J Endod. 2016;42(7):1114-9. https://doi.org/10.1016/j.joen.2016.04.007 [ Links ]

7 Martins MP, Duarte MAH, Cavenago BC, Kato AS, et al. Effectiveness of the ProTaper Next and Reciproc Systems in Removing Root Canal Filling Material with Sonic or Ultrasonic Irrigation: A Micro-computed Tomographic Study. J Endod. 2017;43(3):467-71. https://doi.org/10.1016/j.joen.2016.10.040 [ Links ]

8 Penha da Silva PJ, Marceliano-Alves MF, Provenzano JC, Dellazari RLA, et al. Quality of Root Canal Filling Using a Bioceramic Sealer in Oval Canals: A Three-Dimensional Analysis. Eur J Dent. 2021;15(3):475-80. https://doi.org/10.1055/s-0040-1722095 [ Links ]

9 Tavares SJO, Gomes CC, Marceliano-Alves MF, Guimaraes LC, et al. Supplementing filling material removal with XP-Endo Finisher R or R1-Clearsonic ultrasonic insert during retreatment of oval canals from contralateral teeth. Aust Endod J. 2021;47(2):188-94. https://doi.org/10.1111/aej.12451 [ Links ]

10 Crozeta BM, Silva-Sousa YTC, Leoni GB, Mazzi-Chaves JF, et al. Micro-Computed Tomography Study of Filling Material Removal from Oval-shaped Canals by Using Rotary, Reciprocating, and Adaptive Motion Systems. J Endod. 2016;42(5):793-7. https://doi.org/10.1016/j.joen.2016.02.005 [ Links ]

11 Monguilhott Crozeta B, Damiao de Sousa-Neto M, Bianchi Leoni G, Francisco Mazzi-Chaves J, et al. A micro-computed tomography assessment of the efficacy of rotary and reciprocating techniques for filling material removal in root canal retreatment. Clin Oral Investig. 2016;20(8):2235-40. https://doi.org/10.1007/s00784-016-1728-0 [ Links ]

12 Bago I, Suk M, Katic M, Gabric D, Anic I. Comparison of the effectiveness of various rotary and reciprocating systems with different surface treatments to remove gutta-percha and an epoxy resin-based sealer from straight root canals. Int Endod J. 2019;52(1): 105-13. https://doi.org/10.1111/iej.12985 [ Links ]

13 Tagger M, Tamse A, Katz A, Korzen BH. Evaluation of the apical seal produced by a hybrid root canal filling method, combining lateral condensation and thermatic compaction. J Endod. 1984;10(7):299-303. https://doi.org/10.1016/S0099-2399(84)80183-1 [ Links ]

14 Bago I, Plotino G, Katic M, Roían M, Batinic M, Anic I. Evaluation of filling material remnants after basic preparation, apical enlargement and final irrigation in retreatment of severely curved root canals in extracted teeth. Int Endod J. 2020;53(7):962-73. https://doi.org/10.1111/iej.13287 [ Links ]

15 Weissheimer T, Heck L, Calefi PHS, Alcalde MP, et al. Evaluation of the mechanical properties of different nickel-titanium retreatment instruments. Australian Endodontic Journal. 2021;47(2):265-72. https://doi.org/10.1111/aej.12474 [ Links ]

16 Ozyürek T, Demiryürek EO. Efficacy of different nickel-titanium instruments in removing gutta-percha during root canal retreatment. J Endod. 2016;42(4):646-9. https://doi.org/10.1016/j.joen.2016.01.007 [ Links ]

17 Monguilhott Crozeta B, Damiao de Sousa-Neto M, Bianchi Leoni G, Francisco Mazzi-Chaves J, et al. A micro-computed tomography assessment of the efficacy of rotary and reciprocating techniques for filling material removal in root canal retreatment. Clin Oral Investig. 2016;20(8):2235-40. https://doi.org/10.1007/s00784-016-1728-0 [ Links ]

18 Rios M de A, Villela AM, Cunha RS, Velasco RC, et al. Efficacy of 2 reciprocating systems compared with a rotary retreatment system for gutta-percha removal. J Endod. 2014;40(4):543-6. https://doi.org/10.1016/jjoen.2013.11.013 [ Links ]

19 Rodig T, Reicherts P, Konietschke F, Dullin C, Hahn W, Hülsmann M. Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT. Int Endod J. 2014;47(10):942-8. https://doi.org/10.1111/iej.12239 [ Links ]

20 Rossi-Fedele G, Ahmed HMA. Assessment of Root Canal Filling Removal Effectiveness Using Micro-computed Tomography:ASystematicReview.JEndod.2017;43(4):520-6. https://doi.org/10.1016/jjoen.2016.12.008 [ Links ]

21 Bernardes RA, Duarte MAH, Vivan RR, Alcalde MP, et al. Comparison of three retreatment techniques with ultrasonic activation in flattened canals using micro-computed tomography and scanning electron microscopy. Int Endod J. 2016;49(9):890-7. https://doi.org/10.1111/iej.12522 [ Links ]

22 Bago I, Suk M, Katic M, Gabric D, Anic I. Comparison of the effectiveness of various rotary and reciprocating systems with different surface treatments to remove gutta-percha and an epoxy resin-based sealer from straight root canals. Int Endod J. 2019;52(1): 105-13. https://doi.org/10.1111/iej.12985 [ Links ]

23 Alves FRF, Marceliano-Alves MF, Sousa JCN, Silveira SB, et al. Removal of root canal fillings in curved canals using either reciprocating single- or rotary multi-instrument systems and a supplementary step with the XP-Endo Finisher. J Endod. 2016;42(7): 1114-9. https://doi.org/10.1016/j.joen.2016.04.007 [ Links ]

24 Jorgensen B, Williamson A, Chu R, Qian F. The Efficacy of the WaveOne Reciprocating File System versus the ProTaper Retreatment System in Endodontic Retreatment of Two Different Obturating Techniques. J Endod. 2017;43(6): 1011-1013. https://doi.org/10.1016/j.joen.2017.01.018 [ Links ]

25 Suk M, Bago I, Katic M, Snjaric D, Munitic MS, Anic I. The efficacy of photon-initiated photoacoustic streaming in the removal of calcium silicate-based filling remnants from the root canal after rotary retreatment. Lasers Med Sci. 2017;32(9):2055-62. https://doi.org/10.1007/s10103-017-2325-4 [ Links ]

FUNDING

This study was supported by grants from Fundajao Carlos Chagas Filho de Amparo á Pesquisa do Estado do Rio de Janeiro (FAPERJ) and Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq), Brazilian Governmental Institutions.

Received: August 2023; Accepted: October 2023

Corresponding Author: Marceliano-Alves Marília mmarceliano@hotmail.com

CONFLICT OF INTEREST

The authors declare no potential conflicts of interest regarding the research, authorship, and/or publication of this article.

Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License