SciELO - Scientific Electronic Library Online

 
vol.96 número1-2QSAR studies on urea and thiourea derivatives: Relationship between descriptors log P, p, MR and MV and antibacterial acvtivity in Staphylococcus aureus, Klebsiella pneumoniae and Escherichia coliThermal decomposittion of the acetone cyclic diperoxide in 1-octanol solution índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


The Journal of Argentine Chemical Society

versão On-line ISSN 1852-1428

Resumo

MONZON, Celina M; DELFINO (H), Mario R; SARNO, María del C  e  DELFINO, Mario R. Phenobarbital in pharmaceutical tablets by modified conductimetrical analysis. J. Argent. Chem. Soc. [online]. 2008, vol.96, n.1-2, pp.101-110. ISSN 1852-1428.

A simple and reliable assay for Phenobarbital in tablets, by modified conductimetric titration was developed. The use of ammonium hydroxide addition enhanced the acidity of Phenobarbital and allowed its indirect determination, with NaOH as titrant. Optimal Work conditions were established to perform assays with tablets containing 100 mg of phenobarbital provided by the Medical Plant of Corrientes (PLAMECOR) Argentina. The proposed method was found to be highly precise, having a relative standard deviation (CV) below 2.0% in repeatability and intermediate precision studies. Using this approach the calibration curve showed r2 = 0.9996 with a linearity range from 50 to 150 mg. Accuracy based on the average recovery of known amounts of drug in placebo was 100.15% ± 1.31, value included inside the limits established by USP. Trivial signal in titration of placebo demonstrated the high specificity of this method. Measurements were compared with determinations by the reference method (HPLC), using two tails Student`s statistical t-test. It was established with a 95% confidence level, that there are no significant differences among results obtained with both methods. The modified conductimetric titration method is preferred due to its simplicity, ease, low cost and absence of pre-treatment procedures of the samples.

Palavras-chave : Conductimetric titration; Phenobarbital; Pharmaceutical quality control.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons